Diagnostic Error Code
FRU/Action
014-197-XXX
Parallel port test warning
1.
Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
014-198-XXX
Parallel port test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Flash update
procedures” on page 259
3. Go to “Undetermined problems” on page 73
014-199-XXX
Parallel port test failed, cause unknown
1. Go to “Undetermined problems” on page 73
2. Flash the system and re-test. See “Flash update
procedures” on page 259
3. Replace component under function test
014-2XX-XXX 014-3XX-XXX
Parallel port failure
1.
External parallel device
2. System board
015-000-XXX
USB port Interface Test Passed
No action
015-001-XXX
USB port Presence
1.
Remove USB device(s) and re-test
2. System board
015-002-XXX
USB port Timeout
1.
Remove USB device(s) and re-test
2. System board
015-015-XXX
USB port External Loopback failure
1.
Remove USB device(s) and re-test
2. System board
015-027-XXX
USB port Configuration/Setup error
1.
Flash the system. See “Flash update procedures”
on page 259
2. System board
015-032-XXX
USB port Device Controller failure
System board
015-034-XXX
USB port buffer allocation failure
1.
Reboot the system
2. Flash the system and re-test. See “Flash update
procedures” on page 259
3. Run memory test
4. System board
015-035-XXX
USB port Reset condition detected
1.
Remove USB device(s) and re-test
2. System board
015-036-XXX
USB port Register error
System board
015-040-XXX
USB port IRQ failure
1.
Run setup and check for conflicts
2. Flash the system. See “Flash update procedures” on
page 259
3. System board
015-195-XXX
USB port Test aborted by user
Information only
Re-start the test, if necessary
Chapter 9
.
Symptom-to-FRU Index
59
Summary of Contents for 4157 - ThinkStation S20 - 2 GB RAM
Page 1: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 2: ......
Page 3: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 38: ...32 ThinkStation Hardware Maintenance Manual ...
Page 56: ...50 ThinkStation Hardware Maintenance Manual ...
Page 80: ...74 ThinkStation Hardware Maintenance Manual ...
Page 93: ...Chapter 10 Replacing FRUs Type 4105 4157 4217 87 ...
Page 124: ...118 ThinkStation Hardware Maintenance Manual ...
Page 264: ...258 ThinkStation Hardware Maintenance Manual ...
Page 268: ...262 ThinkStation Hardware Maintenance Manual ...
Page 274: ...268 ThinkStation Hardware Maintenance Manual ...
Page 275: ......
Page 276: ...Part Number 53Y4348 Printed in USA 1P P N 53Y4348 53Y4348 ...