Fan power control (FPC) module
The following illustration shows the connectors and LEDs on the FPC module.
Figure 9. FPC connectors and LEDs
Table 8. FPC connectors and LEDs
1
Reset button hole
5
Check log LED (yellow)
2
Power LED (green)
6
Ethernet port activity (RJ-45) LED (green)
3
Activity LED (green)
7
Dedicated Ethernet port for FPC management access
4
Identification LED (blue)
8
Ethernet port link (RJ-45) LED (green)
1
Reset button
: Press the button for 1 to 4 seconds, FPC reboots. Press over 4 seconds, FPC reboots and
loads to the default settings.
2
Power-on LED
: When this LED is lit (green), it indicates that the FPC has power.
3
Activity LED
: When this LED is lit (green), it indicates that the FPC is actively controlling the enclosure.
4
Identification LED
: When this LED is lit (blue), it indicates the enclosure location in a rack.
5
Check log LED
: When this LED is lit (yellow), it indicates that a system error has occurred. Check the FPC
event log for additional information.
6
Ethernet port activity (RJ-45) LED
: When this LED is flashing (green), it indicates that there is activity
through the remote management and console (Ethernet) port over the management network.
7
Dedicated Ethernet port for FPC management access
: Use this connector to access FPC management.
8
Ethernet port link (RJ-45) LED
: When this LED is lit (green), it indicates that there is an active connection
through the remote management and console (Ethernet) port to the management network.
Power supplies
The NeXtScale n1200 DWC Enclosure Type 5468 supports six autoranging power supplies.
The power supplies get electrical power from a 200 - 240 V ac power source and convert the ac input into 12
V outputs. The power supplies are capable of autoranging within the input voltage range. There is one
common power domain for the enclosure that distributes power to each of the DWC tray and modules
through the system midplane.
Chapter 2
.
Solution components
19
Summary of Contents for 5468
Page 4: ...ii ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Setup Guide ...
Page 18: ...14 ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Setup Guide ...
Page 32: ...28 ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Setup Guide ...
Page 70: ...66 ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Setup Guide ...
Page 78: ...74 ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Setup Guide ...
Page 82: ...78 ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Setup Guide ...
Page 86: ...82 ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Setup Guide ...
Page 89: ......
Page 90: ...Part Number SP47A36229 Printed in China 1P P N SP47A36229 1PSP47A36229 ...