2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Check IBM Support site for Service Bulletins/RETAIN tips related to an Over Temperature
Condition.
5. If the problem persists and there are no other DIMMs with the same indication, replace the
DIMM.
Related links
– Server features and specifications
– Removing a compute book
– Replacing a compute book
– Removing the compute book cover
– Replacing the compute book cover
– Removing a memory module
– Replacing a memory module
•
806f0a13-2401ffff : A Fatal Bus Error has occurred on bus [SensorElementName].
IMM has reported a Bus Fatal Error.
May also be shown as 806f0a132401ffff or 0x806f0a132401ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0244
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
Related links
– Finding the UEFI (POST) error code
•
806f0b13-0701ffff : Bus [SensorElementName] is operating in a degraded state.
IMM has detected that the DMI Bus is degraded.
May also be shown as 806f0b130701ffff or 0x806f0b130701ffff
Severity
Warning
Serviceable
yes
Automatically notify support
no
Appendix C. Integrated management module II (IMM2) error messages
1351
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......