Explanation:
Memory SMI Link Failure Memory SMI Link Failure
Severity
Warning
User Response
Complete the following steps:
1. Remove the compute book, and ensure the Processor heatsink is fully screwed down
2. (Trained service technician only) Remove affected Processor and inspect Processor socket pins
for damaged or mis-aligned pins. If damage is found, replace the compute book.
•
W.580B1 Memory SMI Lane Redundancy Lost Memory SMI Lane Redundancy Lost
Explanation:
Memory SMI Lane Redundancy Lost Memory SMI Lane Redundancy Lost
Severity
Warning
User Response
Complete the following steps:
1. Remove the compute book, and ensure the Processor heatsink is fully screwed down
2. (Trained service technician only) Remove affected Processor and inspect Processor socket pins
for damaged or mis-aligned pins. If damage is found, replace the compute book.
•
W.68002 A CMOS battery error has been detected CMOS Battery Fault
Explanation:
A CMOS battery error has been detected CMOS Battery Fault
Severity
Error
User Response
Complete the following steps:
1. If the system was recently Installed, Moved, or Serviced, make sure the battery is properly
seated.
2. Check IBM support site for an applicable service bulletin or firmware update that applies to this
error.
3. Replace CMOS Battery
4. Replace the standard I/O book.
•
W.680B4 Internal QPI Link Half Width Reduction Detected Internal QPI Link Half Width Reduction
Detected
Explanation:
Internal QPI Link Half Width Reduction Detected Internal QPI Link Half Width Reduction
Detected
Severity
Warning
User Response
Complete the following steps:
1. Remove compute books, and check for damaged connectors on the compute book, and check
for bent pins on the midplane. Replace any damaged hardware.
2. Ensure all Processor heatsinks are fully screwed down
3. (Trained service technician only) Remove affected Processor and inspect Processor socket pins
for damaged or mis-aligned pins. If damage is found, replace the compute book.
Appendix D. UEFI/POST error codes
1949
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......