Table 44. Symptoms and user actions for monitor and video problems
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
Parts listing, System x3850 X6 and x3950 X6 Type 6241
” on page 201 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by
(Trained service technician only)
, that step must be performed only by a
Trained service technician.
Symptom
Action
Monitor or video not available
or displays blank/distorted
images.
1. Make sure that the monitor cables are firmly connected.
2. If the server is attached to a KVM switch, bypass the KVM switch to eliminate it
as a possible cause of the problem; connect the monitor cable to the correct
connector on the rear of the server. If the video now works, replace the KVM
switch.
3. Replace the standard I/O book.
The monitor works when you
turn on the server, but the
screen goes blank when you
start some application
programs.
1. Make sure that:
• The application program is not setting a display mode that is higher than the
capability of the monitor.
• You installed the necessary device drivers for the application.
• The application requirements for the video are compatible with the video
capabilities of the server.
Wrong characters appear on
the screen.
1. Verify that the language and locality settings are correct for the keyboard and
operating system.
2. If the wrong language is displayed, update the server firmware to the latest level
(see “Updating the firmware ” on page 119) with the correct language.
3. Reseat the monitor cable.
Network connectivity problems
Use this information to solve network connectivity problems.
182
System x3850 X6 and x3950 X6 Installation and Service Guide
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......