Diagnostic Error Code
FRU/Action
071-199-XXX
Audio port test failed, cause unknown
1. See “Undetermined problems” on page 69
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 560
3. Replace component under function test
071-25X-XXX
Audio port failure
1.
Speakers
2. Audio card, if installed
3. System board
080-000-XXX
Game Port interface Test Passed
No action
080-XXX-XXX
Game Port interface Error
1.
Remove the game port device and re-test the
system
080-195-XXX
Game Port interface Test aborted by user
Information only
Re-start the test, if necessary
080-196-XXX
Game Port interface test halt, error
threshold exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
080-197-XXX
Game Port interface test warning
1.
Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 43
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
080-198-XXX
Game Port interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 43
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 560
3. Go to “Undetermined problems” on page 69
080-199-XXX
Game Port interface test failed, cause
unknown
1. See “Undetermined problems” on page 69
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 560
3. Replace component under function test
086-000-XXX
Mouse Port interface Test Passed
No action
086-001-XXX
Mouse Port interface Presence
1.
Mouse
2. System board
086-032-XXX
Mouse Port interface Device controller
failure
1.
Mouse
2. System board
086-035-XXX
Mouse Port interface Reset
1.
Mouse
2. System board
086-040-XXX
Mouse Port interface IRQ failure
1.
Run Setup
2. Mouse
3. System board
086-195-XXX
Mouse Port interface Test aborted by user
Information only
Re-start the test, if necessary
086-196-XXX
Mouse Port interface test halt, error
threshold exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter 7
.
Symptom-to-FRU index
61
Summary of Contents for 7220AGU - ThinkCentre M58p Desktop
Page 2: ......
Page 8: ...vi ThinkCentre Hardware Maintenance Manual ...
Page 17: ...Chapter 2 Safety information 9 ...
Page 21: ...Chapter 2 Safety information 13 ...
Page 22: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Page 23: ...Chapter 2 Safety information 15 ...
Page 29: ...Chapter 2 Safety information 21 ...
Page 33: ...Chapter 2 Safety information 25 ...
Page 42: ...34 ThinkCentre Hardware Maintenance Manual ...
Page 50: ...42 ThinkCentre Hardware Maintenance Manual ...
Page 54: ...46 ThinkCentre Hardware Maintenance Manual ...
Page 78: ...70 ThinkCentre Hardware Maintenance Manual ...
Page 566: ...558 ThinkCentre Hardware Maintenance Manual ...
Page 570: ...562 ThinkCentre Hardware Maintenance Manual ...