This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0036
User Action:
Complete the following steps until the problem is solved:
1. Check the event log of System Management Module (SMM) and XClarify Controller (XCC) for any fan-
or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in
place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the microprocessor 1 heat sink is securely installed.
5. Make sure that the microprocessor 1 heat sink is installed correctly and the thermal material is
correctly applied.
6. (Trained technician only) Replace microprocessor 1.
•
FQXSPPU0002G: The Processor [ProcessorElementName] is operating in a Degraded State.
This message is for the use case when an implementation has detected a Processor is running in the
Degraded state.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - CPU
SNMP Trap ID: 42
CIM Prefix: PLAT CIM ID: 0038
User Action:
Complete the following steps:
1. Check the event log of system management module and xClarity Controller for any fan or cooling-
related issues or power-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in
place and correctly installed.
•
FQXSPPU2001I: An Over-Temperature Condition has been removed on [ProcessorElementName].
This message is for the use case when an implementation has detected a Over-Temperature Condition
has been Removed for Processor.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0037
User Action:
110
ThinkSystem D2 Enclosure, Modular Enclosure, Modular Enclosure for 6U Configuration and ThinkSystem SD530 Compute
Node Messages and Codes Reference