Table 3. Events organized by severity (continued)
Event ID
Message String
Severity
FQXSFMA0033M
Intel Optane DCPMM persistent memory interleave set has [arg1]
DCPMMs(DIMM [arg2]), [arg3] DIMMs' location is not correct.
Warning
FQXSFMA0034M
DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memory
interleave set should be moved to DIMM slot [arg3] in sequence.
Warning
FQXSFMA0035M
Intel Optane DCPMM interleave set should have [arg1] DCPMMs, but
[arg2] DCPMMs are missing.
Warning
FQXSFMA0036M
DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memory
interleave set is missing.
Warning
FQXSFMA0037G
Intel Optane DCPMM interleave set (DIMM [arg1]) is migrated from
another system (Platform ID: [arg2]), these migrated DCPMMs are not
supported nor warranted in this system.
Warning
FQXSFMA0038K
All Intel Optane DCPMMs could not be auto unlocked because of no
passphrase.
Warning
FQXSFMA0039K
One or more Intel Optane DCPMMs could not be auto unlocked
because of invalid passphrase.
Warning
FQXSFMA0040K
Invalid Intel Optane DCPMM configuration detected. Please verify
DCPMM configuration is valid.
Warning
FQXSFMA0041K
Near Memory/Far Memory ratio (1:[arg1].[arg2]) for Intel Optane
DCPMM configuration is not in recommended range (1:2 - 1:16).
Warning
FQXSFMA0047M
SPD CRC checking failed on DIMM [arg1]. [arg2]
Warning
FQXSFPU0021G
Hardware physical presence is in asserted state.
Warning
FQXSFPU0022G
The TPM configuration is not locked.
Warning
FQXSFPU0023G
Secure Boot Image Verification Failure Warning.
Warning
FQXSFPU0033G
Processor has been disabled.
Warning
FQXSFPU0062F
System uncorrected recoverable error happened in Processor [arg1]
Core [arg2] MC bank [arg3] with MC Status [arg4], MC Address [arg5],
and MC Misc [arg6].
Warning
FQXSFPU4033F
TPM Firmware recovery is in progress. Please DO NOT power off or
reset system.
Warning
FQXSFPU4035M
TPM Firmware recovery failed. TPM chip may be damaged.
Warning
FQXSFPU4040M
TPM selftest has failed.
Warning
FQXSFPU4043G
TPM Firmware update aborted. System is rebooting...
Warning
FQXSFPU4045G
Physical Presence is not asserted, abort TPM Firmware upgrade.
Warning
FQXSFPU4050G
Failed to update TPM Firmware.
Warning
FQXSFPU4051G
Undefined TPM_TCM_POLICY found
Warning
FQXSFPU4052G
TPM_TCM_POLICY is not locked
Warning
FQXSFPU4053G
System TPM_TCM_POLICY does not match the planar.
Warning
FQXSFPU4054G
TPM/TCM card logical binding has failed.
Warning
FQXSFPW0001L
CMOS has been cleared.
Warning