Severity: Error
User Action:
1. Restart BMC via supported method and reboot the system.
2. Perform AC reset or virtual reseat.
Note:
When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
3. Reflash the LXPM.
4. If the problem persists, contact technical support.
•
FQXPMNM0001G: Failed to set new BMC network parameters.
Severity: Warning
User Action:
1. Ensure input parameters are valid.
2. Wait for one minute and retry the setting.
3. Restart BMC via supported method and reboot the system.
4. Retry the setting change.
5. Use UEFI setup to change parameters (optional).
•
FQXPMNM0002I: Set BMC network parameters to new values.
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMOS0001K: Bootx64.efi is not found. Failed to Boot OS.
Severity: Warning
User Action:
1. Restart BMC via supported method and reboot the system.
2. Reflash BMC firmware.
3. Reboot system and retry OS booting.
4. Perform AC reset or virtual reseat.
Note:
When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
5. If the problem persists, contact technical support.
•
FQXPMOS0002K: Failed to read Deployment Manager Signature from USB.
Severity: Warning
User Action:
1. Ensure proper operation of the virtual USB connection.
2. Restart BMC via supported method and reboot the system.
3. If the problem persists, reflash BMC firmware.
4. Retry OS deployment.
200
ThinkSystem D2 Enclosure, Modular Enclosure, Modular Enclosure for 6U Configuration and ThinkSystem SD530 Compute
Node Messages and Codes Reference
Summary of Contents for 7X20
Page 225: ......