Severity: Warning
User Action:
1. Reseat SMM module.
2. If 3V3_SENSE warning is still asserted, replace SMM module.
•
0201001C: 5V_SENSE: Voltage sensor, warning event was asserted, reading value %V (Threshold
%V)
Asserted when voltage sensed on 5V power rail is lower than lower critical threshold or higher than upper
critical threshold
Severity: Warning
User Action:
1. Reseat SMM module.
2. If 5V_SENSE warning is still asserted, replace SMM module.
•
0201001D: 2V5_SENSE: Voltage sensor, warning event was asserted, reading value %V (Threshold
%V)
Asserted when voltage sensed on 2.5V power rail is lower than lower critical threshold or higher than
upper critical threshold
Severity: Warning
User Action:
1. Reseat SMM module.
2. If 2V5_SENSE warning is still asserted, replace SMM module.
•
0201001E: 1V2_SENSE: Voltage sensor, warning event was asserted, reading value %V (Threshold
%V)
Asserted when voltage sensed on 1.2V power rail is lower than lower critical threshold or higher than
upper critical threshold
Severity: Warning
User Action:
1. Reseat SMM module.
2. If 1V2_SENSE warning is still asserted, replace SMM module.
•
0201001F: 1V15_SENSE: Voltage sensor, warning event was asserted, reading value %V (Threshold
%V)
Asserted when voltage sensed on 1.15V power rail is lower than lower critical threshold or higher than
upper critical threshold
Severity: Warning
User Action:
1. Reseat SMM module.
2. If 1V15_SENSE warning is still asserted, replace SMM module.
•
0201021A: 12V_SENSE: Voltage sensor, critical event was asserted, reading value %V (Threshold
%V)
Asserted when voltage sensed on 12V power rail is lower than lower critical threshold or higher than upper
critical threshold
Severity: Critical