5. After you install qualified memory and power up the server, check to ensure this informational event
is not logged again.
•
FQXSFMA0008I: DIMM [arg1] POST memory test failure has been recovered. [arg2]
Severity: Info
User Action:
Information only; no action is required.
•
FQXSFMA0008M: DIMM [arg1] has failed the POST memory test. [arg2]
Severity: Error
User Action:
Complete the following steps:
1. If the DIMM configuration was changed prior to this failure verify that the DIMMs are installed in the
correct population sequence.
2. RESEAT the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot
to F1 setup and enable the DIMM. Reboot the system.
3. If the DIMMs have been upgraded just prior to the issue than update uEFI to the latest version.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
•
FQXSFMA0011I: Memory population change detected. [arg1]
Severity: Info
User Action:
Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected, then
please ignore this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
•
FQXSFMA0027K: Invalid memory configuration (Unsupported DIMM Population) detected. Please
verify memory configuration is valid.[arg1]
Severity: Error
User Action:
Complete the following steps:
1. This event could follow an uncorrectable memory error or failed memory test. Check the log and
resolve that event first. DIMMs disabled by other errors or actions could cause this event.
2. Ensure that the DIMM are populated in the correct sequence, according to the service information for
this product.
3. If DIMMs are present and properly installed, check for any lit DIMM connector error LEDs, and if
found, reseat those DIMMs, then check logs for memory diagnostic codes.
4. Reset UEFI to default settings.
5. If problem persists, update UEFI firmware.
6. If the problem persists, collect Service Data logs.
7. Contact Lenovo Support.
•
FQXSFMA0029L: The [arg1] PFA Threshold limit has been exceeded on DIMM [arg2]. [arg3]
Severity: Error
.
133
Summary of Contents for 7Y51
Page 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Page 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Page 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Page 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Page 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Page 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Page 175: ......
Page 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...