1. Check XCC logs.
2. Review power policies and system configuration settings in the XCC GUI.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFSM0003N: Timed Out waiting on boot permission from Management Module: System
Halted.
Severity: Warning
User Action:
Complete the following steps:
1. Check XCC logs.
2. Review power policies and system configuration settings in the XCC GUI.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFSM0004M: An XCC communication failure has occurred.
Severity: Warning
User Action:
Complete the following steps:
1. AC cycle the system.
2. Make sure XCC and UEFI FW are operating with same compatible level.
3. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
error.
4. Reflash XCC Firmware.
5. If the problem persists, collect Service Data logs.
6. Contact Lenovo Support.
•
FQXSFSM0007I: The XCC System Event log (SEL) is full.
Severity: Info
User Action:
Complete the following steps:
1. Use BMC Web Interface to clear event logs.
2. If BMC communication is unavailable, use F1 Setup to access System Event Logs Menu and Choose
Clear BMC System Event Logs and Restart Server.
•
FQXSFSM0008M: Boot permission timeout detected.
Severity: Error
User Action:
Complete the following steps:
1. Review XCC logs for communication errors and resolve.
2. AC cycle the system.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFSR0001M: [arg1] GPT corruption detected, DiskGUID: [arg2]
.
141
Summary of Contents for 7Y51
Page 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Page 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Page 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Page 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Page 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Page 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Page 175: ......
Page 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...