Severity: Warning
User Action:
Complete the following steps:
1. Remove all the external drive during POST to avoid this event false triggered.
2. Check the XCC event log, if this event has a follow up recovery event log, means GTP corruption has
been recovered successfully, then ignore this event message and do not perform the remaining
steps.
3. Back up the data disk.
4. Press F1 Setup->SystemSettings->Recovery->Disk GPT Recovery and set to "Automatic."
5. Save settings and restart the system.
6. Boot to F1 setup; system automatically tries to recover the GPT during the POST.
7. Restart the system.
8. Re-format the LUN or disk and re-install the OS.
9. If the problem persists, collect Service Data logs.
10. Contact Lenovo Support.
•
FQXSFSR0002I: [arg1] GPT corruption recovered, DiskGUID: [arg2]
Severity: Info
User Action:
Information only; no action is required.
•
FQXSFSR0003G: The number of boot attempts has been exceeded. No bootable device found.
Severity: Warning
User Action:
Complete the following steps:
1. Remove AC power from the system.
2. Connect at least one bootable device ot the system.
3. Connect AC power to the system.
4. Power on system and retry.
5. If the problem persists, collect Service Data logs.
6. Contact Lenovo Support.
•
FQXSFTR0001L: An invalid date and time have been detected.
Severity: Warning
User Action:
Complete the following steps:
1. Check the XCC event logs. This event should immediately precede an FQXSFPW0001L error.
Resolve that event or any other battery related errors.
2. Use F1 Setup to reset date and time.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
142
ThinkSystem SR250 Messages and Codes Reference
Summary of Contents for 7Y51
Page 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Page 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Page 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Page 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Page 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Page 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Page 175: ......
Page 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...