Severity: Info
User Action:
Information only; no action is required.
•
FQXPMRS0011K: Failed to change disk drives' state.
Severity: Warning
User Action:
1. Ensure LXPM and RAID adapter firmware are at the latest levels.
2. Ensure the state of the RAID adapter and disk drives are both normal.
3. Verify proper physical connection of the disk drive and RAID adapter.
4. Reboot the machine and retry to change disk drives' state.
5. If the error still occurs, contact service to support.
•
FQXPMSD0001M: HDD Test was interrupted by the host with a hardware or software reset
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, RAID card, backplane, and all related cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the error still occurs, contact service to support.
•
FQXPMSD0002M: A fatal error or unknown test error occurred while the device was executing its
self-test
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, RAID card, backplane, and all related cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the error still occurs, contact service to support.
•
FQXPMSD0003M: self-test completed having a test element that failed and the test element that
failed is not known.
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, RAID card, backplane, and all related cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the error still occurs, contact service to support.
•
FQXPMSD0004M: self-test completed having the electrical element of the test failed.
Severity: Error
User Action:
156
ThinkSystem SR250 Messages and Codes Reference
Summary of Contents for 7Y51
Page 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Page 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Page 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Page 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Page 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Page 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Page 175: ......
Page 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...