1. Ensure the proper connection of hard drives, RAID card, backplane, and all related cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the error still occurs, contact service to support.
•
FQXPMSD0005M: self-test completed having the servo (and/or seek) test element of the test failed.
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, RAID card, backplane, and all related cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the error still occurs, contact service to support.
•
FQXPMSD0006M: self-test completed having the read element of the test failed.
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, RAID card, backplane, and all related cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the error still occurs, contact service to support.
•
FQXPMSD0007M: Hard Drive(s) not found
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, RAID card, backplane, and all related cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the error still occurs, contact service to support.
•
FQXPMSD0008M: UEFI is not ready for LXPM to send command to test hard drive.
Severity: Error
User Action:
1. Please run the test again later.
2. If this message is still reported, please run the latest version of SMART tool on OS which is open
source tool and could be downloaded from website to check hard drive status.
•
FQXPMSD0009M: Device error is occurred when LXPM send command to test hard drive.
Severity: Error
User Action:
1. Please run the test again later.
2. If this message is still reported, please run the latest version of SMART tool on OS which is open
source tool and could be downloaded from website to check hard drive status.
.
XClarity Provisioning Manager events
157
Summary of Contents for 7Y51
Page 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Page 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Page 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Page 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Page 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Page 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Page 175: ......
Page 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...