1. If the event still exists, replace the fan.
•
FQXSPCA0007J: Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted.
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Temperature
SNMP Trap ID: 12
CIM Prefix: PLAT CIM ID: 0490
User Action:
Complete the following steps until the problem is solved:
1. Check the XCC event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
correctly installed in place.
3. Make sure that the room temperature is in the range in the operating specifications.
•
FQXSPCA0009M: Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted.
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0494
User Action:
Complete the following steps until the problem is solved:
1. Check the XCC event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers/airduct
are correctly installed in place.
3. Make sure that the room temperature is in the range in the operating specifications.
•
FQXSPCA0011N: Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted.
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor
going high has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0498
User Action:
26
ThinkSystem SR250 Messages and Codes Reference
Summary of Contents for 7Y51
Page 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Page 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Page 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Page 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Page 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Page 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Page 175: ......
Page 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...