User Action:
Information only; please correct the error recorded in system log to resolve the error
•
FQXSPIO0011N: An Uncorrectable Error has occurred on [SensorElementName].
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0240
User Action:
Check http://support.lenovo.com/for TECH tips or firmware updates that might correct the error.
1. Make sure that all I/O expansion adapters have correct and matching levels of device drivers and
firmware.
2. Check the system-event log for additional information about failing components.
3. If there are no entries related to the error in the XCC event log, contact service for further support
•
FQXSPIO2000J: The connector [PhysicalConnectorElementName] has been disconnected.
This message is for the use case when an implementation has detected a Connector was Disconnected.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0265
User Action:
Information only; no action is required
•
FQXSPIO2001I: The connector [PhysicalConnectorElementName] configuration error has been
repaired.
This message is for the use case when an implementation has detected an Interconnect Configuration
was Repaired.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0267
User Action:
Information only; no action is required
•
FQXSPIO2002I: The System [ComputerSystemElementName] has detected a POST Error
deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity: Info
Serviceable: No
46
ThinkSystem SR250 Messages and Codes Reference
Summary of Contents for 7Y51
Page 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Page 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Page 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Page 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Page 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Page 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Page 175: ......
Page 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...