This message is for the use case when an implementation has detected a Power Supply failure is
predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0088
User Action:
Complete the following steps:
1. Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
2. Check power supply LEDs:
a. If AC LED is not lit, check power cord and input voltage. once the problem still exist, then replace
the power supply.
b. If power supply model is no AC LED, then please power off the system then reseat PSU and
reboot system
c. If problem still exist, please send system event log to service for further investigation.
•
FQXSPPW0005I: [PowerSupplyElementName] is operating in an Input State that is out of range.
This message is for the use case when an implementation has detected a Power Supply that has input out
of range.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0098
User Action:
Please check system spec to ensure the configuration is within spec.
•
FQXSPPW0006I: [PowerSupplyElementName] has lost input.
This message is for the use case when an implementation has detected a Power Supply that has input
that has been lost.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0100
User Action:
Make sure power cables are connected correctly.
•
FQXSPPW0007L: [PowerSupplyElementName] has a Configuration Mismatch.
This message is for the use case when an implementation has detected a Power Supply with a
Configuration Error.
Severity: Error
86
ThinkSystem SR250 Messages and Codes Reference
Summary of Contents for 7Y51
Page 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Page 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Page 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Page 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Page 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Page 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Page 175: ......
Page 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...