3. If the problem remains, contact service for further support
4. Contact local service provider. To locate a reseller authorized by Lenovo to provide warranty service,
go to http://www.ibm.com/partnerworld and click Business Partner Locator.
•
FQXSPPW0101J: Redundancy Degraded for [RedundancySetElementName] has asserted.
This message is for the use case when Redundancy Degraded has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0804
User Action:
Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
•
FQXSPPW0104J: Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or
Fully Redundant to Non-redundant:Sufficient.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0806
User Action:
Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
•
FQXSPPW0110M: Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted.
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Redundant Power Supply
SNMP Trap ID: 9
CIM Prefix: PLAT CIM ID: 0810
User Action:
Complete the following steps until the problem is solved:
1. Check if any power supply is missing, failing or not installed properly. If so, re-install or replace it.
2. Check the power supply max rate and power capping policy. If the required power resource is not
met, change the power supply or modify power capping mechanism on XCC web GUI.
•
FQXSPPW2001I: [PowerSupplyElementName] has been removed from container
[PhysicalPackageElementName].
90
ThinkSystem SR250 Messages and Codes Reference
Summary of Contents for 7Y51
Page 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Page 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Page 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Page 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Page 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Page 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Page 175: ......
Page 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...