Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver and
any required firmware updates.
2. If this device and/or any attached cables were recently installed, moved, serviced or upgraded.
a. a.Reseat Adapter and any attached cables.
b. b.Reload Device Driver.
c. c.If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2
settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports ->PCIe
Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
d. d.If a PCIe error has also been reported on a second slot within the same node, please ensure
steps a, b, and c above are also performed for that adapter before proceeding.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFIO0032M: PCIe Correctable Error PFA Threshold limit has been exceeded at Bus [arg1]
Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The
physical bay number is [arg6].
Severity: Warning
User Action:
Complete the following steps:
1. Reboot the system.
2. Reflash the NVME disk firmware.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFIO0033J: PCIe Link Width has degraded from [arg1] to [arg2] in physical bay number [arg3].
Severity: Warning
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe NVME disk, and resolve that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure that the PCIe NVME disk, is installed in the compatible bay and
a compatible cable is used. If not, performance of this device might be impacted.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
•
FQXSFIO0034J: PCIe Link Speed has degraded from [arg1] to [arg2] in physical bay number [arg3].
Severity: Warning
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe NVME disk, and resolve that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
150
ThinkSystem SR630 V2 Messages and Codes Reference
Summary of Contents for 7Z70
Page 1: ...ThinkSystem SR630 V2 Messages and Codes Reference Machine Types 7Z70 and 7Z71 ...
Page 4: ...ii ThinkSystem SR630 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SR630 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SR630 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SR630 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SR630 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......