Chapter 3. UEFI events
UEFI error messages can be generated when the server starts up (POST) or while the server is running. UEFI
error messages are logged in the Lenovo XClarity Controller event log in the server.
For each event code, the following fields are displayed:
Event identifier
An identifier that uniquely identifies an event.
Event description
The logged message string that appears for an event.
Explanation
Provides additional information to explain why the event occurred.
Severity
An indication of the level of concern for the condition. The severity is abbreviated in the event log to the
first character. The following severities can be displayed:
•
Informational
. The event was recorded for audit purposes, usually a user action or a change of states
that is normal behavior.
•
Warning
. The event is not as severe as an error, but if possible, the condition should be corrected
before it becomes an error. It might also be a condition that requires additional monitoring or
maintenance.
•
Error
. The event is a failure or critical condition that impairs service or an expected function.
User Action
Indicates what actions you should perform to solve the event. Perform the steps listed in this section in
the order shown until the problem is solved. If you cannot solve the problem after performing all steps,
contact Lenovo Support.
UEFI events organized by severity
The following table lists all UEFI events, organized by severity (Information, Error, and Warning).
Table 3. Events organized by severity
Event ID
Message String
Severity
FQXSFDD0012I
SATA Hard Drive Error: [arg1] was recovered.
Informational
FQXSFIO0005I
An intra-board UPI has been disabled on the link between processor
[arg1] port [arg2] and processor [arg3]port [arg4] because of UPI
topology downgrade.
Informational
FQXSFIO0006I
An inter-board UPI has been disabled on the link between processor
[arg1] port [arg2] and processor [arg3]port [arg4] because of UPI
topology downgrade.
Informational
FQXSFIO0015I
IFM: System reset performed to reset adapters.
Informational
FQXSFIO0018I
IFM: Configuration too large for compatibility mode.
Informational
FQXSFIO0020J
PCIe Isolation has occurred in PCIe slot [arg1]. The adapter may not
operate correctly.
Informational
© Copyright Lenovo 2022
135
Summary of Contents for 7Z70
Page 1: ...ThinkSystem SR630 V2 Messages and Codes Reference Machine Types 7Z70 and 7Z71 ...
Page 4: ...ii ThinkSystem SR630 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SR630 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SR630 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SR630 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SR630 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......