• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Diagnostic
code
Message
Description
Action
I.18009
[I.18009] A core speed
mismatch has been
detected for one or
more processor
packages.
Processors have
mismatched Core
Speed.
1. Make sure the microprocessor is supported
by the blade server. See http://www.ibm.com
/systems/info/x86servers/ serverproven/
compat/us/.
2. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
3. Run the Setup utility and select
System
Information
→
System Summary
→
Processor Details
to view the
microprocessor information to compare the
installed microprocessor specifications.
4. (Trained technician only) Remove and
replace one of the microprocessors so that
they both match (see “Removing a
microprocessor and heat sink” on page 61
and “Installing a microprocessor and heat
sink” on page 65).
I.1800A
[I.1800A] A mismatch
has been detected
between the speed at
which a QPI link has
trained between two or
more processor
packages.
Processors have
mismatched Bus Speed.
1. Make sure the microprocessor is supported
by the blade server. See http://www.ibm.com
/systems/info/x86servers/ serverproven/
compat/us/.
2. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
3. Run the Setup utility and select
System
Information
→
System Summary
→
Processor Details
to view the
microprocessor information to compare the
installed microprocessor specifications.
4. (Trained technician only) Remove and
replace one of the microprocessors so that
they both match (see “Removing a
microprocessor and heat sink” on page 61
and “Installing a microprocessor and heat
sink” on page 65).
86
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...