• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Diagnostic
code
Message
Description
Action
S.51006
[S.51006] A memory
mismatch has been
detected. Please verify
that the memory
configuration is valid.
One or More
Mismatched DIMMs
Detected.
Make sure that the DIMMs have been installed in
the correct sequence (see “Installing a memory
module” on page 47).
S.51009
[S.51009] No system
memory has been
detected.
No Memory Detected.
1. Make sure that there is at least one DIMM
installed in the server.
2. If there are no memory faults recorded in the
logs and no DIMM connector error LEDs are
lit, make sure that all DIMM connectors are
enabled by using the Setup utility or the
Advance Settings Utility (ASU).
3. Reinstall all DIMMs in the correct population
sequence (see “Installing a memory module”
on page 47 for more information).
91
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...