• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Diagnostic
code
Message
Description
Action
W.580A2
[W.580A2] Invalid
memory configuration
for Sparing Mode.
Please correct the
memory configuration.
Unsupported DIMM
Population for Spare
Mode.
1. If a DIMM connector error LED is lit on the
system board, check the event logs and
follow the procedure for that event and
restart the server.
2. Make sure that the DIMMs have been
installed in the correct sequence for sparing
mode (see “Installing a memory module” on
page 47).
I.580A4
[I.580A4] Memory
population change
detected.
DIMM Population
Change Detected.
Information only. Memory has been added,
moved, or changed.
I.580A5
[I.580A5] Mirror fail-over
complete. DIMM
number % has failed
over to the mirrored
copy.
DIMM Mirror Fail-over
Detected.
Information only. Memory redundancy has been
lost. Check the event log for uncorrected DIMM
failure events (see “Event logs” on page 79).
I.580A6
[I.580A6] Memory spare
copy has completed
successfully.
Spare Copy Complete.
Information only. Memory redundancy or spare
rank has been lost. Check the event log for
uncorrected DIMM failure events (see “Event
logs” on page 79).
I.58015
[I.58015] Memory spare
copy initiated.
Spare Copy Started.
No action; information only.
W.68002
[W.68002] A CMOS
battery error has been
detected.
CMOS Battery Fault.
1. Reseat the battery.
2. Clear the CMOS memory (see “System-
3. Replace the following components one at a
time in the order shown, restarting the server
each time:
• Battery (see “Removing the battery” on
page 41 and “Installing the battery” on
page 42).
• (Trained technician only) System board.
94
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...