• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Diagnostic
code
Message
Description
Action
• Select
Planar Ethernet (PXE/DHCP)
to
disable the on-board Ethernet controller
ROM.
• Select
Advanced Functions
, followed by
PCI Bus Control
, and then
PCI ROM
Control Execution
to disable the ROM of
the adapters in the PCI slots.
• Select
Devices and I/O Ports
to disable
any of the on-board devices.
3. If the problem remains, replace the following
components one at a time in the order
shown, restarting the server each time:
• Expansion cards (see “Removing an I/O
expansion card” on page 50 and
“Installing an I/O expansion card” on page
53).
• (Trained technician only) Replace the
system board (see “Removing the system-
board assembly” on page 71 and
“Installing the system-board assembly” on
page 71).
S.3020007
[S.3020007] A firmware
fault has been detected
in the UEFI image.
Internal UEFI Firmware
Fault Detected, System
halted.
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Recover the server firmware (see
“Recovering from a UEFI update failure” on
page 254).
3. (Trained technician only) Replace the system
board (see “Removing the system-board
assembly” on page 71 and “Installing the
system-board assembly” on page 71).
S.3028002
[S.3028002] Boot
permission timeout
detected.
Boot Permission
Negotiation Timeout.
1. Check the IMM event logs (see “IMM error
messages” on page 105) for communication
errors and follow the actions to resolve the
error.
2. Reseat the blade server (see “Removing the
3. If the problem remains, contact your IBM
service representative for support.
98
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...