• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Diagnostic
code
Message
Description
Action
W.3808003
[W.3808003] Unable to
retrieve the system
configuration from the
IMM.
Error Retrieving System
Configuration from IMM.
1. Run the Setup utility, save the configuration,
and restart the server (see “Using the Setup
utility” on page 11).
2. Update the IMM2 firmware (see “Updating
firmware and device drivers” on page 23).
3. (Trained technician only) If the problem
remains, replace the system board (see
“Removing the system-board assembly” on
page 71 and “Installing the system-board
assembly” on page 71).
I.3808004
[I.3808004] The IMM
System Event Log (SEL)
is full.
IPMI System Event Log
is Full.
Run the Setup utility to clear IMM2 logs and
restart the server (see “Using the Setup utility” on
page 11).
I.3818001
[I.3818001] The
firmware image capsule
signature for the
currently booted flash
bank is invalid.
Current Bank CRTM
Capsule Update
Signature Invalid.
1. Run the Setup utility (see “Using the Setup
utility” on page 11), select
Load Default
Settings
, and save the settings.
2. Recover the server firmware (see
“Recovering from a UEFI update failure” on
page 254).
3. (Trained technician only) Replace the system
board (see “Removing the system-board
assembly” on page 71 and “Installing the
system-board assembly” on page 71).
I.3818002
[I.3818002] The
firmware image capsule
signature for the non-
booted flash bank is
invalid.
Opposite Bank CRTM
Capsule Update
Signature Invalid.
1. Run the Setup utility (see “Using the Setup
utility” on page 11), select
Load Default
Settings
, and save the settings.
2. Recover the server firmware (see
“Recovering from a UEFI update failure” on
page 254).
3. (Trained technician only) Replace the system
board (see “Removing the system-board
assembly” on page 71 and “Installing the
system-board assembly” on page 71).
I.3818003
[I.3818003] The CRTM
flash driver could not
lock the secure flash
region.
CRTM Could not lock
secure flash region.
1. Run the Setup utility (see “Using the Setup
utility” on page 11), select
Load Default
Settings
, and save the settings.
2. Recover the server firmware (see
“Recovering from a UEFI update failure” on
page 254).
3. (Trained technician only) Replace the system
board (see “Removing the system-board
assembly” on page 71 and “Installing the
system-board assembly” on page 71).
103
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...