• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
Action
0x80070200
80070217-3102ffff
Error
PCI express bus 2,
Expansion Card
(CIOv Fault) critical
Complete the following
steps:
1. Remove any recently
installed CIOv Card.
2. Power on the node. If
the node can be
powered-on
successfully,
complete the steps
below:
a. Check the
ServerProven
website to make
sure that the
recently installed
components are
compatible with
the compute
node.
b. Inspect the
previously
installed
components for
physical damage.
3. If the node cannot be
powered-on
successfully, or if this
is not the first
occurrence of the
problem, you need to
replace the CIOv
Card.
0x80070200
80070219-0701ffff
Error
System board,
chip set (SysBrd
Fault) critical
1. Make sure that the
latest firmware is
being used (see
“Updating firmware
and device drivers”
on page 23).
2. Reseat the blade
server in the
BladeCenter (see
“Removing the blade
server from the
BladeCenter unit” on
page 39 and
“Installing the blade
server in a
126
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...