• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
Action
BladeCenter unit” on
page 39).
3. Reset the UEFI
firmware settings to
default values using
the Setup utility (see
“Using the Setup
utility” on page 11).
4. Clear the CMOS data
by removing the
system battery for 30
seconds (see
“Removing the
battery” on page 41
and “Installing the
battery” on page 42).
5. (Trained technician
only) Replace the
system-board
assembly (see
“Removing the
system-board
assembly” on page
71 and “Installing the
system-board
assembly” on page
71).
0x80070300
80070301-0301ffff
80070301-0302ffff
Error
Processor
X
,
temperature (CPU
X
OverTemp) non-
recoverable [Note:
X
=1, 2]
1. Check the system
event log for
additional
temperature and fan
information (see
“Event logs” on page
79).
2. Make sure that the
room temperature is
within the operating
specifications (see
“Features and
specifications” on
page 2).
3. Make sure that none
of the air vents on the
BladeCenter unit and
on the blade server
are blocked.
4. Make sure that all of
the fans on the
127
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...