• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
Action
0x80080000
80080128-2101ffff
Information
System mgmt
software, blade
mgmt subsystem
health (Low
Security Jmp)
present
Information only. No
corrective actions
required.
0x800b0100
800b010c-2581ffff
Error
Group 1, (memory
device 1-16)
memory (Backup
Memory) is not
redundant
1. Check the event logs
for other memory
errors that might
occur (see “Event
logs” on page 79).
2. Reseat all of the
memory modules in
the blade server (see
“Removing a memory
module” on page 45
and “Installing a
memory module” on
page 47).
3. Make sure all of the
memory is enabled in
the Setup utility (see
“Using the Setup
utility” on page 11).
Notice which memory
modules are disabled
before continuing to
the next step.
133
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...