• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
Action
heat sink” on page 61
and “Installing a
microprocessor and
heat sink” on page
65).
5. (Trained technician
only) If the error
continues, replace the
system-board
assembly (see
“Removing the
system-board
assembly” on page
71 and “Installing the
system-board
assembly” on page
71).
0x806f0009
806f0009-0701ffff
Information
System board,
(Power Unit Stat)
power off
Information only. No
action is required.
0x806f000d
806f000d-0401ffff
806f000d-0402ffff
Error
Hard drive
X
,
(Drive
X
) removed
[Note
X
=0,1]
Install the storage drive
(see “Installing a hot-swap
storage drive” on page
44).
0x806f000f
806f000f-220101xx
806f000f-220102xx
806f000f-220103xx
806f000f-220104xx
806f000f-220107xx
806f000f-22010axx
806f000f-22010bxx
806f000f-22010cxx
806f000f-2201ffff
Error
FW/BIOS,
firmware progress
(ABR Status) error
Install the latest UEFI
firmware (see “Recovering
from a UEFI update
failure” on page 254).
0x806f000f
806f000f-
220101xx806f000f-
220102xx 806f000f-
220103xx 806f000f-
220104xx 806f000f-
220107xx 806f000f-
22010axx 806f000f-
22010bxx 806f000f-
22010cxx 806f000f-
2201ffff
Error
FW/BIOS,
firmware progress
(Firmware Error)
error
Install the latest UEFI
firmware (see “Recovering
from a UEFI update
failure” on page 254).
138
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...