• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
Action
microprocessor
socket pins for any
damaged pins. If a
damage is found,
replace the system-
board assembly (see
“Removing the
system-board
assembly” on page
71 and “Installing the
system-board
assembly” on page
71).
7. (Trained technician
only) Replace the
affected
microprocessor (see
“Removing a
microprocessor and
heat sink” on page 61
and “Installing a
microprocessor and
heat sink” on page
65).
0x806f010c
806f010c-2581ffff
Error
Group 1 (All
DIMMs)
uncorrectable
ECC memory error
1. Refer to TIP H21455
for minimum code
level.
2. Check the IBM
support website for
an applicable retain
tip or firmware update
that applies to this
memory error.
3. Install the affected
memory modules (as
indicated by the error
LEDs on the system
board or the event
logs) to a different
memory channel or
microprocessor (see
“Installing a memory
module” on page 47
for memory
population
sequence).
4. If the error still occurs
on the same memory
module, replace the
147
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...