• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
Action
microprocessor
socket pins for any
damaged pins. If a
damage is found,
replace the system-
board assembly (see
“Removing the
system-board
assembly” on page
71 and “Installing the
system-board
assembly” on page
71).
7. (Trained technician
only) Replace the
affected
microprocessor (see
“Removing a
microprocessor and
heat sink” on page 61
and “Installing a
microprocessor and
heat sink” on page
65).
0x806f010d
806f010d-0401ffff
806f010d-0402ffff
Error
Hard drive
X
(Drive
X
) fault [Note
X
=
0,1]
Replace the storage drive
(see “Removing a hot-
swap storage drive” on
page 44 and “Installing a
hot-swap storage drive”
on page 44).
0x806f010f
806f010f-2201ffff
Error
FW/BIOS,
firmware progress
(Firmware Error)
hang
Install the latest UEFI
firmware (see “Recovering
from a UEFI update
failure” on page 254).
150
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...