• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
Action
4. (Trained technician
only) If the error
continues, replace the
system-board
assembly (see
“Removing the
system-board
assembly” on page
71 and “Installing the
system-board
assembly” on page
71).
0x806f030c
806f030c-2001ffff
806f030c-2002ffff
806f030c-2003ffff
806f030c-2004ffff
806f030c-2005ffff
806f030c-2006ffff
806f030c-2007ffff
806f030c-2008ffff
806f030c-2009ffff
806f030c-200affff
806f030c-200bffff
806f030c-200cffff
806f030c-200dffff
806f030c-200effff
806f030c-200fffff
806f030c-2010ffff
Error
Memory device
X
(DIMM
X
) memory
scrub failed [Note:
X
=1-16]
1. Refer to TIP H21455
for minimum code
level.
2. Check the IBM
support website for
an applicable retain
tip or firmware update
that applies to this
memory error.
3. Install the affected
memory modules (as
indicated by the error
LEDs on the system
board or the event
logs) to a different
memory channel or
microprocessor (see
“Installing a memory
module” on page 47
for memory
population
sequence).
4. If the error still occurs
on the same memory
module, replace the
affected memory
module.
5. (Trained technician
only) If the problem
occurs on the same
DIMM connector,
check the DIMM
connector. If the
connector is
damaged, replace the
system-board
assembly (see
156
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...