Error Code
Event ID
Type
Error Message
Action
system-board
assembly” on page
71 and “Installing the
system-board
assembly” on page
71).
0x806f0413
806f0413-2582ffff
Error
Group 2, (PCI
express bus 1-2,
Expansion Module
2-0)
• (All PCI Error)
PCI parity error,
• (One of PCI
Error) PCI parity
error, or,
• (PCIs) PCI
parity error
1. If this blade and/or
any attached cables
were recently
installed, moved,
serviced, or
upgraded, perform
the following steps:
a. Reseat the
adapter and any
attached cables.
b. Reload the device
driver.
c. If the device is not
recognized, re-
configure slot to
Gen1 or Gen2.
d. You can configure
Gen1/Gen2
settings in F1
Setup.
1) Go to
System
Settings
→
Devices and
I/O Ports
→
PCIe Gen1/
Gen2/Gen3
Speed
Selection
, or
the
ASU
Utility
.
2. Check IBM support
website for an
applicable device
driver, firmware
update, pdsg revision
or other information
that applies to this
error.
3. Load new device
driver and any
162
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...