• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
Action
9. Replace the
expansion unit (see
“Removing an
optional expansion
unit” on page 58 and
“Installing an optional
expansion unit” on
page 59).
10. If the system contains
multiple
microprocessors,
swap the
microprocessors (see
“Removing a
microprocessor and
heat sink” on page 61
and “Installing a
microprocessor and
heat sink” on page
65).
11. (Trained technician
only) If the error
continues, replace the
system-board
assembly (see
“Removing the
system-board
assembly” on page
71 and “Installing the
system-board
assembly” on page
71).
0x806f0813
806f0813-2581ffff
Error
Group 1, (memory
device 1-16)
(DIMMs) bus
uncorrectable
error
1. Check the operating
system event log and
the system event log
as it may contain
additional information
(see “Event logs” on
page 79).
2. Reseat the blade
server in the
BladeCenter (see
“Removing the blade
server from the
BladeCenter unit” on
page 39 and
“Installing the blade
183
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...