Error code
Description
Action
516-040-064
Aborted the test because the device was busy.
1. Make sure that no critical operation (for
example, firmware download) is already running.
2. Wait until the critical operation is complete;
then, run the test again.
3. If the failure remains, restart the OneCommand
Manager daemon.
4. Turn off and restart the blade server; then, rerun
the test. See “Turning off the blade server” on
page 7 and “Turning on the blade server” on
page 6.
516-000-000
Passed the loopback test at the MAC layer.
N/A
516-040-001
Failed the loopback test at the MAC layer.
1. Make sure that the component firmware or
driver is installed correctly, upgrade if
necessary; then, rerun the test.
2. Make sure the OneCommand Manager daemon
is running.
3. Turn off and restart the blade server; then, rerun
the test. See “Turning off the blade server” on
page 7 and “Turning on the blade server” on
page 6.
4. If the failure remains, reinstall the device driver
and OneCommand Manager.
516-040-064
Aborted the test because the device was busy.
1. Make sure that no critical operation (for
example, firmware download) is already running.
2. Wait until the critical operation is complete;
then, run the test again.
3. If the failure remains, restart the OneCommand
Manager daemon.
4. Turn off and restart the blade server; then, rerun
the test. See “Turning off the blade server” on
page 7 and “Turning on the blade server” on
page 6.
516-000-000
Passed the loopback test at the physical layer.
N/A
234
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...