Error code
Description
Action
4. If the blade server has stopped responding, turn
off and restart the blade server; then, rerun the
test. See “Turning off the blade server” on page
7 and “Turning on the blade server” on page 6.
5. (Trained technician only) If the component
failure remains, refer to Chapter 4 “Removing
and replacing blade server components” on
page 37 to replace the failed component.
089-901-xxx
Failed the CPU stress test.
1. If the blade server has stopped responding, turn
off and restart the blade server; then, rerun the
test. See “Turning off the blade server” on page
7 and “Turning on the blade server” on page 6.
2. Make sure that the DSA Diagnostic code is up-
to-date, upgrade if necessary; then, rerun the
test. up-to-date, upgrade if necessary. The
latest code can be found on the IBM support
website at http://www-933.ibm.com/ support/
fixcentral/systemx/groupView? query.
productGroup=ibm%2FBladeCenter.
3. Make sure that the system firmware level is up-
to-date, upgrade if necessary; then, rerun the
test. The installed firmware level can be found in
the DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found on the IBM support website at http://
www-933.ibm.com/ support/fixcentral/systemx/
groupView? query.productGroup=ibm%
2FBladeCenter.
4. If the blade server has stopped responding, turn
off and restart the blade server; then, rerun the
test.
5. (Trained technician only) If the component
failure remains, refer to Chapter 4 “Removing
and replacing blade server components” on
page 37 to replace the failed component.
Memory self tests
Use this information to diagnose and resolve memory-self test errors.
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
237
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...