• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error code
Description
Action
215-802-xxx
Aborted the optical drive self test due to media
tray being open.
1. Close the media tray and wait 15 seconds. See
your BladeCenter documentation for information
about the optical drive (media tray).
2. Rerun the test. See “Diagnostic tools overview”
3. Insert a new CD or DVD into the drive and wait
for 15 seconds for the media to be recognized;
then, rerun the test. See “Diagnostic tools
overview” on page 78.
4. Make sure that the cable for the optical drive is
securely connected at both ends of the cable
and tighten any loose connections. See your
BladeCenter documentation for information
about the optical drive (media tray).
5. Make sure that the cable for the optical drive is
not damaged and replace the cable if damage is
present. See your BladeCenter documentation
for information about the optical drive (media
tray).
6. Rerun the test. See “Diagnostic tools overview”
7. Make sure that the DSA Diagnostic code is at
the latest level, upgrade if necessary. The latest
code can be found at http://www.ibm.com/
support/docview.wss?uid=psg1SERV-DSA
8. Rerun the test. See “Diagnostic tools overview”
9. For additional troubleshooting information, go to
http://www-947.ibm.com/support/entry/portal/
docdisplay?lndocid=MIGR-41559.
10. Rerun the test. See “Diagnostic tools overview”
11. Replace the CD or DVD drive (media tray). See
your BladeCenter documentation for information
about replacing the optical drive.
12. If the failure remains, collect the data from the
DSA event log and send it to IBM Service. For
information about contacting and sending data
to IBM Service, see “Hardware service and
support” on page 267.
215-803-xxx
Failed the optical drive self test due to the disk
possibly being in use by the system.
1. Wait for the system activity to stop; then, rerun
the test. See .
2. Turn off and turn on the system, then; rerun the
test. See “Turning off the blade server” on page
7, “Turning on the blade server” on page 6 and
“Diagnostic tools overview” on page 78.
249
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...