Step 10. Install the cover onto the blade server (see “Installing the blade server cover” on page 73).
Step 11. Install the blade server into the BladeCenter unit (see “Installing the blade server in a BladeCenter
Step 12. Turn on the blade server, start the Setup utility, and reset the configuration (see “Using the Setup
utility” on page 11 for instructions).
Removing a hot-swap storage drive
Use this information to remove a hot-swap storage drive.
The blade server has two hot-swap storage bays for installing or removing hot-swap storage devices. To
remove a hot-swap hard disk drive or drive filler, complete the following steps.
Step 1. Before you begin, read “Safety” on page iii and “Installation guidelines” on page 37.
Step 2. If possible, save the data on your drive, especially if it is part of a RAID array, before you remove it
from the blade server.
Step 3. Press the release latch (orange) on the storage drive to release the drive handle.
Step 4. Pull the release handle to remove the drive from the storage bay.
Step 5. If you are instructed to return the storage drive, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Installing a hot-swap storage drive
Use these instructions to install a hot-swap storage drive into the blade server.
The blade server has two storage bays for installing hot-swap storage drives. One storage drive might
already be installed in the blade server in storage bay 0. If the blade server is equipped with one storage
drive, you can install an additional drive in storage bay 1. The blade server supports using RAID 0 or RAID 1
when two storage drives of the same interface type are installed. See “Configuring a RAID array” on page 25
for information about SAS RAID configuration.
To install a hot-swap storage drive or drive filler, complete the following steps.
44
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...