• If using Installation Tool A, twist the handle on the microprocessor tool assembly
counterclockwise to the open position to insert the microprocessor into the socket, and lift
the installation tool out of the socket.
• If using Installation Tool B, twist the handle of the installation tool assembly
counterclockwise until the microprocessor is inserted into the socket, and lift the installation
tool out of the socket. The following illustration shows the tool handle in the open position.
E5-x6xx
E5-x6xx v2
H
L
Figure 5. Installation Tool B
Figure 6. Installation tool handle adjustment
Attention:
• Do not press the microprocessor into the socket.
• Do not touch exposed pins of the microprocessor socket.
• Make sure that the microprocessor is oriented and aligned correctly in the socket before
you try to close the microprocessor retainer.
• Do not touch the thermal material on the bottom of the heat sink or on top of the
microprocessor. Touching the thermal material will contaminate it.
Step 5. Close the microprocessor socket release levers and retainer:
68
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...