Hard disk drive activity LED (green):
When this green LED is lit, it indicates that there is activity on the
storage drive.
Hard disk drive status LED (yellow):
When this yellow LED is lit, it indicates that an error has occurred with
the storage drive. The LED turns off only after the error is corrected.
Turning on the blade server
Use this information to turn on the blade server.
After you connect the blade server to power through the BladeCenter unit, the blade server can start in any of
the following ways:
• You can press the power-control button on the front of the blade server (see “Blade server controls and
LEDs” on page 4) to start the blade server.
Notes:
1. Wait until the power-on LED on the blade server flashes slowly before you press the power-control
button. While the service processor in the blade server is initializing and synchronizing with the
management module, the power-on LED flashes rapidly, and the power-control button on the blade
server does not respond. This process can take approximately two minutes after the blade server has
been installed.
2. While the blade server is starting, the power-on LED on the front of the blade server is lit and does not
flash. See “Blade server controls and LEDs” on page 4 for the power-on LED states.
• If a power failure occurs, the BladeCenter unit and the blade server can be configured to start
automatically when power is restored through the Advanced Management Module.
• You can turn on the blade server remotely by using the management module.
• If the blade server is connected to power (the power-on LED is flashing slowly), the blade server is
communicating with the management module, the operating system supports the Wake on LAN feature,
and the Wake on LAN feature has not been disabled through the management module, the Wake on LAN
feature can turn on the blade server.
6
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...