Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error code
Description
Action
217-000-000
Passed the storage drive self test.
N/A
217-900-xxx
Failed the storage drive self test.
1. Make sure that the storage drive is securely
connected in the storage drive connector, then;
reseat the storage drive.
2. Rerun the test.
3. Make sure that the system BIOS firmware is at
the latest level, upgrade if necessary; then, rerun
the test. The BIOS firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found on the IBM support Web site at http://
www.ibm.com/support/docview.wss?uid=
psg1MIGR-63017.
4. Rerun the test.
5. If the component failure remains, refer to
Chapter 4 “Removing and replacing blade
server components” on page 37 to replace the
failed component.
217-800-xxx
The storage drive self test was terminated by
the user.
N/A
Tape alert flags
Use this information to diagnose and resolve tape alert flags for the blade server.
Tape alert flags are numbered 1 through 64 and indicate a specific media-changer error condition. Each tape
alert is returned as an individual log parameter, and its state is indicated in bit 0 of the 1-byte Parameter
Value field of the log parameter. When this bit is set to 1, the alert is active.
Each tape alert flag has one of the following severity levels:
C - Critical
W - Warning
I - Information
Different tape drives support some or all of the following flags in the tape alert log:
Flag 2: Library Hardware B (W)
This flag is set when an unrecoverable mechanical error occurs.
Flag 4: Library Hardware D (C)
This flag is set when the tape drive fails the power-on self-test or a
mechanical error occurs that requires a power cycle to recover. This flag is internally cleared when the
drive is powered-off.
253
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...