Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_LINK_SPEED_DETECTION_MISMATCH ( dataRateMismatch.html )
MEL_EV_DFC_CTL_MISWIRE - 0x151E
This event occurs when: This error is logged only for controllers with integrated drive channel ports. When
two ESMs in the same drive tray are connected to different channels from the same controller. This error is
reported for both channel ports involved in the miswire.
Event Name - Controller Miswire
Event description: Controller miswire for drive channel occurred
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Channel Port (0x2, 0x3)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DFC_MIXED_LOOP_TECHNOLOGY_MISWIRE - 0x1522
This event occurs when: Information not available.
Event Name - Drive Enclosure Type Miswire
Event description: Drive enclosure type miswire
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
.
193
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......