Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_SAS_PORT_DEGRADED ( failedSASPort.html )
MEL_EV_DSAS_WPORT_DEG_TO_FAIL - 0x1707
This event occurs when: An attached device is determined to be present, but none of the PHYs that
comprise the port attached to that device can connect to or communicate with the device.
Event Name - Degraded Wide Port Becomes Failed
Event description: Degraded wide port becomes failed
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_SAS_PORT_FAILED ( failedSASPort.html )
MEL_EV_DSAS_EXP_PORT_DEV_MISWIRE - 0x170A
This event occurs when: Information not available.
Event Name - DSAS Exp Port Dev Miswire
Event description: Drive expansion port miswire
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is not provided with this event.
198
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......