Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_WRONG_SECTOR_SIZE
RecoveryFailureType - REC_DRIVE_INCOMPATIBLE_SECTOR_SIZE ( sectorSizeIncompatible.html )
MEL_EV_DRV_FORMAT_FAILED - 0x224B
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x86 indicating
the controller set the drive state to Failed Format failure.
Event Name - Drive Format Failed
Event description: Drive failed - initialization failure
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DRV_NO_RESPONSE - 0x224D
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x85 indicating
the controller set the drive state to Failed No Response.
Event Name - Drive No Response
Event description: Drive failed - no response at start of day
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FAILED_DRIVE ( failedDrive.html )
MEL_EV_RECON_DRV_FAILED - 0x224E
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x82 indicating
the controller set the drive state to Failed be it was unable to make the drive usable after replacement.
.
213
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......