MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_INVALID_POWER_SUPPLY ( invalidPowerSupply.html )
MEL_EV_SBB_MISMATCHED_ENCL_EEPROM_CONTENTS - 0x2303
This event occurs when: The contents of the EEPROMs on the midplanes are not matched.
Event Name - Mismatched Midplane EEPROM Contents
Event description: Mismatched midplane EEPROM contents
Event Group - SBB Validation
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_TRAY_ID
RecoveryFailureType - REC_MISMATCHED_MIDPLANE_EEPROMS ( mismatched_midplane_eeproms.html )
MEL_EV_SBB_TWO_WIRE_INTERFACE_BUS_FAILURE - 0x2304
This event occurs when: A failure is detected on the two wire interface bus.
Event Name - Two Wire Interface Bus Failure
Event description: Two wire interface bus failure
Event Group - SBB Validation
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_TRAY_ID
RecoveryFailureType - REC_FAILED_I2C_BUS ( failed_i2c_bus.html )
MEL_EV_SBB_VPD_EEPROM_CORRUPTION - 0x2305
This event occurs when: VPD data in the Storage Bridge Bay EEPROM is corrupted.
Event Name - VPD EEPROM Corruption
Event description: VPD EEPROM corruption
224
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......