Event Group - SBB Validation
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_TRAY_ID
RecoveryFailureType - REC_CORRUPT_VPD_EEPROM ( corrupt_vpd_eeprom.html )
MEL_EV_CONTROLLER - 0x2500
This event occurs when: A controller is removed from an array configured to use dual controllers.
Event Name - Controller Removed
Event description: Controller removed
Event Group - Hot Swap
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_REMOVED_CONTROLLER ( removedCtrl.html )
MEL_EV_ACS_ERROR - 0x2602
This event occurs when: An auto code synchronization failed.
Event Name - ACS Error
Event description: Automatic controller firmware synchronization failed
Event Group - Start of Day
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
.