Event Name - Redundant Power Supply Required
Event description: Redundant power-fan canisters required - only one power-fan canister detected
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Power Supply (0x0, 0x2)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_REDUNDANT_PS_REQUIRED ( noRedundancyPowerFanPS.html )
MEL_EV_INVALID_ENCLOSURE_SETTING - 0x284F
This event occurs when: Needed.
Event Name - Invalid Enclosure Setting
Event description: Misconfigured tray
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_ENCLOSURE_MISCONFIGURED ( misconfiguredTray.html )
MEL_EV_FACTORY_DEFAULT_MISMATCH - 0x2852
This event occurs when: Two IOMs (ESMs) in an enclosure report different factory default VPD data, and the
automated correction of this condition is unsuccessful.
Event Name - Factory Def Mismatch
Event description: IOM (ESM) configuration settings version mismatch
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
238
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......