MEL_EV_SAFE_TIER_NON_COMPLIANCE - 0x5403
This event occurs when: The limits of a premium feature have been exceeded (e.g. 6 storage partitions
mapped when 4 have been purchased).
Event Name - Tier Non-Compliance
Event description: Premium feature exceeds limit
Event Group - SAFE
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Relative (0x0, 0x0)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SNAPSHOT_NOT_COMPLIANT ( nonCompliantSnapshot.html )
MEL_EV_SAFE_MISMATCHED_GK_DEP - 0x5405
This event occurs when: Each controller of the pair has a different setting for the NVSRAM bit that controls
whether or not the controller is subject to Gold Key restrictions. When this condition is detected, both
controllers are treated as though they are subject to the restrictions.
Event Name - Mismatched Gold Key Settings
Event description: Gold Key - mismatched settings
Event Group - SAFE
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Relative (0x0, 0x0)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MISMATCHED_GOLD_KEY_SETTINGS
MEL_EV_SAFE_MISMATCHED_MDT_DEP - 0x5406
This event occurs when: Each controller of the pair has a different setting for the NVSRAM bit that controls
whether or not Mixed Drive Types is a premium feature. When this condition is detected, both controllers are
treated as though MDT is a premium feature.
Event Name - Mismatched Mixed Drive Type Settings
Event description: Mixed drive types - mismatched settings
254
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......