RecoveryFailureType - REC_BATTERY_OVERTEMP ( batteryOverTemp.html )
MEL_EV_INSUFFICIENT_LEARNED_CAPACITY - 0x7301
This event occurs when: Measured capacity of the BBU is insufficient to hold cache data for at least 72
hours.
Event Name - Insufficient Learned Capacity
Event description: Insufficient learned battery capacity
Event Group - Battery Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Battery Pack (0x0, 0x9)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_SMART_BATTERY
RecoveryFailureType - REC_BATTERY_WARN ( batteryReplacementRequired.html )
MEL_EV_BATTERY_MISSING - 0x7306
This event occurs when: Information not available.
Event Name - Battery Missing
Event description: Battery missing
Event Group - Battery Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Battery Pack (0x0, 0x9)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_SMART_BATTERY
RecoveryFailureType - REC_REMOVED_BATTERY ( batteryRemoved.html )
MEL_EV_BATTERY_EXPIRED - 0x7308
This event occurs when: Information not available.
Event Name - Battery Expired
Event description: Battery expired
.
265
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......